Crude Oil  Analyser

Advanced GC solution combining detailed hydrocarbon analysis and simulated distillation for highly accurate crude oil boiling point distribution.

Ready to Elevate Your Analysis?

Home » Refinery » Simdist analysers

High-Accuracy Crude Oil Characterisation Using Simdist-DHA Merge

Accurate boiling point distribution data is essential for crude oil valuation, refinery planning and process optimisation. Conventional simulated distillation methods such as ASTM D7169 and ASTM D7500 provide fast results, but can suffer from limited resolution in the C5–C9 range and interference from carbon disulfide used as solvent.

The GAS Crude Oil Analyser – Simdist-DHA Merge combines high-temperature simulated distillation with Detailed Hydrocarbon Analysis (DHA) front-end data according to ASTM D7900. By merging high-resolution DHA data for light hydrocarbons with Simdist results for heavier fractions, the analyser delivers a single, highly accurate True Boiling Point (TBP) report. The system integrates two dedicated GC analysers with a shared autosampler and fully automated calculations in Chromeleon CDS, resulting in improved accuracy, efficient operation and reduced laboratory footprint.

Applications

  • Supported method: ASTM D7900 

    Perform Simdist-DHA merge calculations fully compliant with ASTM D7900.

  • Crude Oil Boiling Point Distribution

    Generate accurate TBP curves by combining DHA front-end and high-temperature Simdist data.

  • Refinery Feedstock Evaluation

    Characterise crude oils for blending, pricing and refinery optimisation.

  • Simulated Distillation Replacement for D86 / D1160

    Use fast, reliable GC-based boiling point determination instead of labour-intensive physical distillation.

  • Laboratory Reference and Method Development

    Support advanced crude oil characterisation with detailed hydrocarbon resolution up to C9.

Benefits

  • More Accurate Simulated Distillation Results
    Improved resolution in the C5–C9 range using DHA data eliminates solvent interference.
  • Single Integrated TBP Report
    DHA and Simdist results are merged into one True Boiling Point curve according to ASTM D7900.
  • Efficient All-in-One Analyser System
    Two GC systems share one autosampler, reducing laboratory space and operational costs.
  • Fully Automated Calculations and Reporting
    Integrated Chromeleon calculation modules eliminate external data processing and reduce errors.
  • Proven, Robust GC Technology
    Based on Thermo Trace GC1600 platforms with PTV injection and backflush for high uptime.

Questions or get a quote?

Interested in our crude oil Simdist-DHA merge analysis solutions?
Contact us today for a personalised quote tailored to your application needs.

Request a quoteTalk to an expert

Eva

Downloads

Access brochures, technical datasheets, application notes, and software updates

Crude Oil Analyser – Simdist-DHA Merge Datasheet

Detailed overview of the Simdist-DHA merge concept, analyser configuration and ASTM D7900 compliant TBP reporting for crude oil analysis.

Download Datasheet

SIMDIST Analysers Datasheet

Comprehensive overview of GC-based simulated distillation solutions compliant with ASTM, IP, ISO and EN methods, including optional DHA merge functionality.

Download Datasheet

Expertise You Can Rely On

With over 40 years of expertise in gas chromatography, GAS provides high-quality, customised analytical solutions for industrial and laboratory applications. The Crude Oil Analyser delivers accurate, and compliant results – ensuring consistent product quality and reliable process monitoring. Contact our experts to discuss a tailored configuration for your specific analytical needs.

Gassite